| Assessment Year | 2025 |
|---|---|
| Principal Product | Aircraft Integrated Drive Generators |
| NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
| SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
| Sales Range | $100 M to 500M |
| # of Employees | 202 |
| Plant Area |
94,000
ft2
|
| Annual Production | 10,000
pieces
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $162,940 | 2,728,800 |
kWh
|
$0.060 |
| Electricity Demand | $155,456 | 10,728 |
kW-mo/yr
|
$14.49 |
| Electricity Fees | $84,539 | - |
|
- |
| TOTAL YEARLY COSTS | $402,935 | |||
| RECOMMENDED SAVINGS* | $76,867 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7221: Lower temperature during the winter season and vice-versa | $24,997 | $1,580 |
$23,702
395,037
kWh
|
$1,295
-
kW-mo/yr
|
|
| 02 | 2.4239: Eliminate or reduce compressed air usage | $10,605 | $780 |
$7,601
126,680
kWh
|
$3,004
-
kW-mo/yr
|
|
| 03 | 2.6218: Turn off equipment when not in use | $27,034 | $2,400 |
$27,034
450,569
kWh
|
- | |
| 04 | 2.7224: Reduce space conditioning during non-working hours | $2,360 | $700 |
$2,360
39,334
kWh
|
- | |
| 05 | 2.7245: Use direct air supply to exhaust hoods | $2,423 | $3,171 |
$1,467
24,448
kWh
|
$956
-
kW-mo/yr
|
|
| 06 | 2.7232: Replace existing hvac unit with high efficiency model | $9,448 | $31,295 |
$5,709
95,160
kWh
|
$3,739
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $76,867 | $39,926 |
$67,873
1,131,228
kWh
|
$8,994
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs