Assessment Year | 2024 |
---|---|
Principal Product | Marine Air Conditioning |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $100 M to 500M |
# of Employees | 180 |
Plant Area |
104,000
ft2
|
Annual Production | 50,000
units
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $126,302 | 2,060,640 |
kWh
|
$0.061 | |
Electricity Demand | $97,281 | 6,448 |
kW-mo/yr
|
$15.09 | |
Electricity Fees | $39,796 | - |
|
- | |
Waste Disposal Costs | |||||
Water Usage | $29,919 | 3,680 |
Tgal
|
$8.13 | |
Water Disposal | $8,537 | 1,325 |
Tgal
|
$6.44 | |
TOTAL YEARLY COSTS | $301,835 | ||||
RECOMMENDED SAVINGS* | $51,569 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,976 | $61,998 |
$7,044
115,474
kWh
|
$8,932
-
kW-mo/yr
|
- | - | - | |
02 | 3.4159: Replace treated water with well / surface water | $15,070 | $13,480 | - | - |
$16,870
-
Tgal
|
- | $(-1,800.0) | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,015 | $1,980 |
$4,730
77,539
kWh
|
$4,285
-
kW-mo/yr
|
- | - | - | |
04 | 2.7221: Lower temperature during the winter season and vice-versa | $6,646 | $700 |
$3,143
51,528
kWh
|
$3,983
-
kW-mo/yr
|
- | - | $(-480.0) | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,413 | $3,096 | - |
$2,413
-
kW-mo/yr
|
- | - | - | |
06 | 2.7442: Keep doors and windows shut when not on use | $1,254 | $320 |
$198
3,240
kWh
|
$1,056
-
kW-mo/yr
|
- | - | - | |
07 | 3.4155: Meter waste water | $1,195 | $900 | - | - | - |
$1,195
-
Tgal
|
- | |
TOTAL RECOMMENDED | $51,569 | $82,474 |
$15,115
247,781
kWh
|
$20,669
-
kW-mo/yr
|
$16,870
-
Tgal
|
$1,195
-
Tgal
|
$(-2,280.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs