ITAC Assessment: MI0443
ITAC logo
ITAC Assessment: MI0443
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Soft Gels
NAICS 325412: Pharmaceutical Preparation Manufacturing
SIC 2834: Pharmaceutical Preparations
Sales Range $50
M
to 100
M
# of Employees 190
Plant Area 72,800
ft2
Annual Production 1,700,000,000
units
Production Hrs. Annual 6,120
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $199,753 3,251,520
kWh
Electricity Demand $94,367 6,245
kW-mo/yr
Electricity Fees $52,770 -
Natural Gas $28,958 7,330
MMBtu
Waste Disposal Costs
Water Usage $50,294 4,160
Tgal
Water Disposal $46,487 4,160
Tgal
TOTAL YEARLY COSTS $472,629
RECOMMENDED SAVINGS* $64,808 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.8114: Change rate schedules or other changes in utility service $18,913 - - - $18,913 -
02 2.2622: Replace existing chiller with high efficiency model $14,162 $54,938 $9,599
157,374
kWh
$4,563
-
kW-mo/yr
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $8,706 $1,980 $6,364
104,330
kWh
$2,342
-
kW-mo/yr
- -
04 2.1221: Replace obsolete burners with more efficient ones $7,616 $18,760 $5,849
95,890
kWh
$2,841
-
kW-mo/yr
- $(-1,074.0)
-
MMBtu
05 2.7425: Clean or color roof to reduce solar load $6,571 $14,916 $4,909
80,467
kWh
$1,662
-
kW-mo/yr
- -
06 2.9112: Use solar heat to heat water $4,071 $12,390 $2,106
34,520
kWh
$997
-
kW-mo/yr
- $968
-
MMBtu
07 2.3132: Recharge batteries on during off-peak demand periods $3,482 $240 - $3,482
-
kW-mo/yr
- -
08 2.7135: Install occupancy sensors $1,287 $501 $1,287
21,091
kWh
- - -
TOTAL RECOMMENDED $64,808 $103,725 $30,114
493,672
kWh
$15,887
-
kW-mo/yr
$18,913 $(-106.0)
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs