Assessment Year | 2024 |
---|---|
Principal Product | Electronic Components |
NAICS | 334419: Other Electronic Component Manufacturing |
SIC | 3679: Electronic Components, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
100,000
ft2
|
Annual Production | 2,000,000
pieces
|
Production Hrs. Annual | 3,223
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $176,153 | 3,135,737 |
kWh
|
$0.056 | |
Electricity Demand | $135,986 | 8,185 |
kW-mo/yr
|
$16.61 | |
Electricity Fees | $9,209 | - |
|
- | |
Waste Disposal Costs | |||||
Water Usage | $6,399 | 1,000 |
Tgal
|
$6.40 | |
Water Disposal | $11,548 | 1,000 |
Tgal
|
$11.55 | |
TOTAL YEARLY COSTS | $339,295 | ||||
RECOMMENDED SAVINGS* | $77,054 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $54,962 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $29,836 | $550 |
$18,190
324,813
kWh
|
$11,646
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $16,559 | $12,210 |
$7,870
140,533
kWh
|
$8,689
-
kW-mo/yr
|
- | |
03 | 2.6218: Turn off equipment when not in use | $14,048 | - |
$14,048
250,859
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,225 | $2,000 |
$4,015
71,694
kWh
|
$2,210
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,323 | $7,394 |
$1,579
28,195
kWh
|
$1,744
-
kW-mo/yr
|
- | |
06 | 3.4159: Replace treated water with well / surface water | $3,200 | $3,460 | - | - |
$3,200
-
Tgal
|
|
07 | 2.7135: Install occupancy sensors | $2,333 | $750 |
$2,333
41,668
kWh
|
- | - | |
08 | 2.4239: Eliminate or reduce compressed air usage | $1,530 | $960 |
$986
17,604
kWh
|
$544
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $77,054 | $27,324 |
$49,021
875,366
kWh
|
$24,833
-
kW-mo/yr
|
$3,200
-
Tgal
|
||
TOTAL IMPLEMENTED | $54,962 | $10,904 |
$38,818
693,165
kWh
|
$16,144
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs