Assessment Year | 2023 |
---|---|
Principal Product | Clinical Diagnostics |
NAICS | 334516: Analytical Laboratory Instrument Manufacturing |
SIC | 3826: Laboratory Analytical Instruments |
Sales Range | $100 M to 500M |
# of Employees | 400 |
Plant Area |
500,000
ft2
|
Annual Production | 4,000
units
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $680,177 | 12,720,155 |
kWh
|
$0.053 | |
Electricity Demand | $378,270 | 21,975 |
kW-mo/yr
|
$17.21 | |
Electricity Fees | $175,310 | - |
|
- | |
Waste Disposal Costs | |||||
Water Usage | $99,351 | 10,707 |
Tgal
|
$9.28 | |
Water Disposal | $59,644 | 4,370 |
Tgal
|
$13.65 | |
TOTAL YEARLY COSTS | $1,392,752 | ||||
RECOMMENDED SAVINGS* | $604,284 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $69,964 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $281,585 | $342,472 |
$194,878
3,676,935
kWh
|
$86,707
-
kW-mo/yr
|
- | - | |
02 | 2.7229: Air condition only space necessary | $92,381 | $7,860 |
$63,875
1,205,191
kWh
|
$28,506
-
kW-mo/yr
|
- | - | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $61,330 | $1,580 |
$25,955
489,709
kWh
|
$35,375
-
kW-mo/yr
|
- | - | |
04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $51,887 | $23,900 |
$35,912
677,581
kWh
|
$15,975
-
kW-mo/yr
|
- | - | |
05 | 2.8114: Change rate schedules or other changes in utility service | $49,124 | $120 | - | - | - | $49,124 | |
06 | 2.7224: Reduce space conditioning during non-working hours | $47,137 | $1,580 |
$47,137
889,381
kWh
|
- | - | - | |
07 | 3.4116: Meter recycled water (to reduce sewer charges) | $11,466 | $1,492 | - | - |
$11,466
-
Tgal
|
- | |
08 | 2.6218: Turn off equipment when not in use | $6,009 | - |
$6,009
113,371
kWh
|
- | - | - | |
09 | 2.7135: Install occupancy sensors | $2,695 | $1,365 |
$2,695
50,851
kWh
|
- | - | - | |
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $670 | $1,980 |
$463
8,742
kWh
|
$207
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $604,284 | $382,349 |
$376,924
7,111,761
kWh
|
$166,770
-
kW-mo/yr
|
$11,466
-
Tgal
|
$49,124 | ||
TOTAL IMPLEMENTED | $69,964 | $4,957 |
$9,167
172,964
kWh
|
$207
-
kW-mo/yr
|
$11,466
-
Tgal
|
$49,124 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs