Assessment Year | 2023 |
---|---|
Principal Product | Shopping carts |
NAICS | 333999: All Other Miscellaneous General Purpose Machinery Manufacturing |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 13 |
Plant Area |
11,214
ft2
|
Annual Production | 6,000
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Puerto Rico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $33,626 | 122,446 |
kWh
|
$0.27 |
Electricity Demand | $12,720 | 1,206 |
kW-mo/yr
|
$10.55 |
Electricity Fees | $2,705 | - |
|
- |
LPG | $57,856 | 1,521 |
MMBtu
|
$38.04 |
TOTAL YEARLY COSTS | $106,907 | |||
RECOMMENDED SAVINGS* | $6,863 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,745 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,311 | $1,060 |
$1,892
6,879
kWh
|
$419
-
kW-mo/yr
|
- | |
02 | 2.3212: Optimize plant power factor | $1,796 | $1,143 | - |
$1,796
-
kW-mo/yr
|
- | |
03 | 2.8114: Change rate schedules or other changes in utility service | $1,322 | $100 | - | - | $1,322 | |
04 | 2.4239: Eliminate or reduce compressed air usage | $1,109 | $910 |
$908
3,303
kWh
|
$201
-
kW-mo/yr
|
- | |
05 | 2.8123: Pay utility bills on time | $325 | - | - | - | $325 | |
TOTAL RECOMMENDED | $6,863 | $3,213 |
$2,800
10,182
kWh
|
$2,416
-
kW-mo/yr
|
$1,647 | ||
TOTAL IMPLEMENTED | $3,745 | $1,970 |
$2,800
10,182
kWh
|
$620
-
kW-mo/yr
|
$325 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs