Assessment Year 2022
Principal Product Plastic Packaging
NAICS 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
SIC 3081: Unsupported Plastics Film and Sheet
Sales Range $10
M
to 50
M
# of Employees 67
Plant Area 42,000
ft2
Annual Production 5,000,000
pieces
Production Hrs. Annual 6,120
hrs
Location (State) Puerto Rico

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $519,155 2,421,239
kWh
Electricity Demand $48,384 5,104
kW-mo/yr
Electricity Fees $3,062 -
TOTAL YEARLY COSTS $570,601
RECOMMENDED SAVINGS* $53,756 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $51,740

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.8114: Change rate schedules or other changes in utility service $17,298 $45,090 $12,634
59,036
kWh
$4,664
-
kW-mo/yr
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $9,075 $5,674 $8,023
37,491
kWh
$1,052
-
kW-mo/yr
-
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $8,550 $2,031 $7,867
36,764
kWh
$683
-
kW-mo/yr
-
04 2.2622: Replace existing chiller with high efficiency model $6,468 $15,450 $6,098
28,493
kWh
$370
-
kW-mo/yr
-
05 2.3212: Optimize plant power factor $5,579 $15,821 - - $5,579
06 3.1161: Eliminate/reduce an operation $4,770 $960 $788
3,682
kWh
$3,982
-
kW-mo/yr
-
07 2.8114: Change rate schedules or other changes in utility service $2,016 $100 - - $2,016
TOTAL RECOMMENDED $53,756 $85,126 $35,410
165,466
kWh
$10,751
-
kW-mo/yr
$7,595
TOTAL IMPLEMENTED $51,740 $85,026 $35,410
165,466
kWh
$10,751
-
kW-mo/yr
$5,579
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings