| Assessment Year | 2022 |
|---|---|
| Principal Product | Plastic Packaging |
| NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 67 |
| Plant Area |
42,000
ft2
|
| Annual Production | 5,000,000
pieces
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | Puerto Rico |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $519,155 | 2,421,239 |
kWh
|
$0.21 |
| Electricity Demand | $48,384 | 5,104 |
kW-mo/yr
|
$9.48 |
| Electricity Fees | $3,062 | - |
|
- |
| TOTAL YEARLY COSTS | $570,601 | |||
| RECOMMENDED SAVINGS* | $53,756 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $51,740 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $17,298 | $45,090 |
$12,634
59,036
kWh
|
$4,664
-
kW-mo/yr
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,075 | $5,674 |
$8,023
37,491
kWh
|
$1,052
-
kW-mo/yr
|
- | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,550 | $2,031 |
$7,867
36,764
kWh
|
$683
-
kW-mo/yr
|
- | |
| 04 | 2.2622: Replace existing chiller with high efficiency model | $6,468 | $15,450 |
$6,098
28,493
kWh
|
$370
-
kW-mo/yr
|
- | |
| 05 | 2.3212: Optimize plant power factor | $5,579 | $15,821 | - | - | $5,579 | |
| 06 | 3.1161: Eliminate/reduce an operation | $4,770 | $960 |
$788
3,682
kWh
|
$3,982
-
kW-mo/yr
|
- | |
| 07 | 2.8114: Change rate schedules or other changes in utility service | $2,016 | $100 | - | - | $2,016 | |
| TOTAL RECOMMENDED | $53,756 | $85,126 |
$35,410
165,466
kWh
|
$10,751
-
kW-mo/yr
|
$7,595 | ||
| TOTAL IMPLEMENTED | $51,740 | $85,026 |
$35,410
165,466
kWh
|
$10,751
-
kW-mo/yr
|
$5,579 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs