Assessment Year 2020
Principal Product Outdoor Furniture
NAICS 337124: Metal Household Furniture Manufacturing
SIC 2514: Metal Household Furniture
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 92,500
ft2
Annual Production 100,000
pieces
Production Hrs. Annual 2,652
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $50,829 1,030,880
kWh
Electricity Demand $50,934 4,582
kW-mo/yr
Electricity Fees $15,201 -
TOTAL YEARLY COSTS $116,964
RECOMMENDED SAVINGS* $29,071 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,059

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $15,103 $21,302 $7,455
152,148
kWh
$7,648
-
kW-mo/yr
02 2.7232: Replace existing hvac unit with high efficiency model $5,241 $20,434 $3,218
65,678
kWh
$2,023
-
kW-mo/yr
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,282 $1,980 $2,059
42,025
kWh
$2,223
-
kW-mo/yr
04 2.4231: Reduce the pressure of compressed air to the minimum required $1,674 $120 $807
16,467
kWh
$867
-
kW-mo/yr
05 2.7135: Install occupancy sensors $1,658 $2,091 $1,658
33,843
kWh
-
06 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $1,113 $2,041 $1,113
22,714
kWh
-
TOTAL RECOMMENDED $29,071 $47,968 $16,310
332,875
kWh
$12,761
-
kW-mo/yr
TOTAL IMPLEMENTED $21,059 $23,402 $10,321
210,640
kWh
$10,738
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs