Assessment Year | 2019 |
---|---|
Principal Product | Marine Air Conditioners |
NAICS | 333413: Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing |
SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
Sales Range | $50 M to 100M |
# of Employees | 180 |
Plant Area |
104,000
ft2
|
Annual Production | 40,000
pieces
|
Production Hrs. Annual | 5,291
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $110,873 | 2,424,600 |
kWh
|
$0.046 |
Electricity Demand | $81,865 | 6,568 |
kW-mo/yr
|
$12.46 |
Electricity Fees | $36,865 | - |
|
- |
TOTAL YEARLY COSTS | $229,603 | |||
RECOMMENDED SAVINGS* | $51,054 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,667 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7245: Use direct air supply to exhaust hoods | $8,536 | $4,314 |
$2,768
60,166
kWh
|
$5,768
-
kW-mo/yr
|
|
02 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $7,058 | $30,007 |
$4,054
88,120
kWh
|
$3,004
-
kW-mo/yr
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,740 | $2,923 |
$3,559
77,359
kWh
|
$2,181
-
kW-mo/yr
|
|
04 | 2.6218: Turn off equipment when not in use | $5,404 | $3,100 |
$5,404
117,468
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,870 | $12,067 |
$3,125
67,937
kWh
|
$1,745
-
kW-mo/yr
|
|
06 | 2.7425: Clean or color roof to reduce solar load | $4,152 | $10,680 |
$3,030
65,870
kWh
|
$1,122
-
kW-mo/yr
|
|
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,680 | $2,020 |
$2,683
58,317
kWh
|
$997
-
kW-mo/yr
|
|
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,489 | $5,529 |
$2,093
45,510
kWh
|
$1,396
-
kW-mo/yr
|
|
09 | 2.7111: Reduce illumination to minimum necessary levels | $3,469 | $1,640 |
$2,148
46,690
kWh
|
$1,321
-
kW-mo/yr
|
|
10 | 2.4323: Use optimum size and capacity equipment | $2,492 | $7,000 |
$1,794
38,998
kWh
|
$698
-
kW-mo/yr
|
|
11 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,617 | $1,707 |
$657
14,291
kWh
|
$960
-
kW-mo/yr
|
|
12 | 2.6218: Turn off equipment when not in use | $547 | $480 |
$323
7,020
kWh
|
$224
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $51,054 | $81,467 |
$31,638
687,746
kWh
|
$19,416
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $21,667 | $25,806 |
$15,161
329,585
kWh
|
$6,506
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs