Assessment Year | 2017 |
---|---|
Principal Product | Electric Coils and Valves |
NAICS | 334416: Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing |
SIC | 3677: Electronic Coils, Transformers, and Other Inductors |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
23,500
ft2
|
Annual Production | 961,000
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Puerto Rico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $79,042 | 456,280 |
kWh
|
$0.17 |
Electricity Demand | $23,927 | 2,512 |
kW-mo/yr
|
$9.53 |
Electricity Fees | $2,626 | - |
|
- |
TOTAL YEARLY COSTS | $105,596 | |||
RECOMMENDED SAVINGS* | $58,893 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,636 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.2515: Use optimum thickness insulation | $17,954 | $21,920 |
$13,821
79,891
kWh
|
$4,133
-
kW-mo/yr
|
- | |
02 | 2.7425: Clean or color roof to reduce solar load | $10,816 | $7,589 |
$8,552
49,435
kWh
|
$2,264
-
kW-mo/yr
|
- | |
03 | 2.6218: Turn off equipment when not in use | $7,233 | $3,600 |
$7,233
41,808
kWh
|
- | - | |
04 | 2.4322: Use or replace with energy efficient substitutes | $6,777 | $5,492 |
$5,217
30,157
kWh
|
$1,560
-
kW-mo/yr
|
- | |
05 | 2.8114: Change rate schedules or other changes in utility service | $5,988 | $6,400 | - | - | $5,988 | |
06 | 2.3212: Optimize plant power factor | $3,370 | $10,745 | - |
$3,370
-
kW-mo/yr
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,256 | $1,660 |
$1,408
8,139
kWh
|
$848
-
kW-mo/yr
|
- | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,121 | $1,508 |
$1,972
11,400
kWh
|
$149
-
kW-mo/yr
|
- | |
09 | 2.2511: Insulate bare equipment | $1,612 | $1,914 |
$1,298
5,694
kWh
|
$313
-
kW-mo/yr
|
- | |
10 | 2.7221: Lower temperature during the winter season and vice-versa | $766 | $400 |
$590
3,409
kWh
|
$176
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $58,893 | $61,228 |
$40,092
229,933
kWh
|
$12,813
-
kW-mo/yr
|
$5,988 | ||
TOTAL IMPLEMENTED | $40,636 | $37,083 |
$32,903
188,376
kWh
|
$7,734
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs