Assessment Year | 2015 |
---|---|
Principal Product | High Volume Hydraulic Cartridges |
NAICS | 332919: Other Metal Valve and Pipe Fitting Manufacturing |
SIC | 3492: Fluid Power Valves and Hose Fittings |
Sales Range | $50 M to 100M |
# of Employees | 267 |
Plant Area |
70,000
ft2
|
Annual Production | 1,560,000
pieces
|
Production Hrs. Annual | 8,008
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $286,894 | 6,196,745 |
kWh
|
$0.046 |
Electricity Demand | $153,550 | 12,347 |
kW-mo/yr
|
$12.44 |
Electricity Fees | $23,197 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $69,185 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $33,804 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7425: Clean or color roof to reduce solar load | $19,094 | $29,862 |
$19,094
415,068
kWh
|
- | |
02 | 2.7292: Lower ceiling to reduce conditioned space | $14,710 | $100,350 |
$14,710
319,780
kWh
|
- | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $12,602 | $80 |
$12,602
273,995
kWh
|
- | |
04 | 2.2437: Recover waste heat from equipment | $7,447 | $6,660 |
$5,296
115,131
kWh
|
$2,151
-
kW-mo/yr
|
|
05 | 2.4323: Use optimum size and capacity equipment | $5,778 | $4,691 |
$2,644
57,487
kWh
|
$3,134
-
kW-mo/yr
|
|
06 | 2.7496: Install partitions to reduce size of conditioned space | $3,819 | $11,872 |
$3,819
83,017
kWh
|
- | |
07 | 2.4239: Eliminate or reduce compressed air usage | $3,433 | $5,370 |
$1,381
30,025
kWh
|
$2,052
-
kW-mo/yr
|
|
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,382 | $40 |
$636
13,823
kWh
|
$746
-
kW-mo/yr
|
|
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $920 | $1,670 |
$472
10,267
kWh
|
$448
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $69,185 | $160,595 |
$60,654
1,318,593
kWh
|
$8,531
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $33,804 | $130,212 |
$33,804
734,848
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs