ITAC Assessment: MI0284
ITAC logo
ITAC Assessment: MI0284
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2015
Principal Product Low Volume Hydraulic Cartridges
NAICS 332919: Other Metal Valve and Pipe Fitting Manufacturing
SIC 3492: Fluid Power Valves and Hose Fittings
Sales Range $50
M
to 100
M
# of Employees 267
Plant Area 55,000
ft2
Annual Production 2,080,000
pieces
Production Hrs. Annual 8,008
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $257,069 5,320,000
kWh
Electricity Demand $146,464 11,813
kW-mo/yr
Electricity Fees $40,765 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $156,782 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $147,179

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.2628: Utilize a less expensive cooling method $77,529 $180,000 $39,994
833,215
kWh
$14,135
-
kW-mo/yr
$23,400
02 2.7292: Lower ceiling to reduce conditioned space $28,449 $55,650 $20,997
437,438
kWh
$7,452
-
kW-mo/yr
-
03 2.7221: Lower temperature during the winter season and vice-versa $28,415 $160 $20,976
436,995
kWh
$7,439
-
kW-mo/yr
-
04 2.4239: Eliminate or reduce compressed air usage $11,198 $6,520 $4,629
96,430
kWh
$6,569
-
kW-mo/yr
-
05 2.4323: Use optimum size and capacity equipment $5,094 $4,691 $4,201
87,516
kWh
$893
-
kW-mo/yr
-
06 2.4231: Reduce the pressure of compressed air to the minimum required $4,302 $40 $3,062
63,794
kWh
$1,240
-
kW-mo/yr
-
07 2.7425: Clean or color roof to reduce solar load $1,588 $2,527 $1,172
24,411
kWh
$416
-
kW-mo/yr
-
08 2.7135: Install occupancy sensors $207 $105 $207
4,310
kWh
- -
TOTAL RECOMMENDED $156,782 $249,693 $95,238
1,984,109
kWh
$38,144
-
kW-mo/yr
$23,400
TOTAL IMPLEMENTED $147,179 $244,857 $87,768
1,828,489
kWh
$36,011
-
kW-mo/yr
$23,400
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings