| Assessment Year | 2015 |
|---|---|
| Principal Product | Waste Water |
| NAICS | 221320: Sewage Treatment Facilities |
| SIC | 4952: Sewerage Systems |
| Sales Range | $10 M to 50M |
| # of Employees | 35 |
| Plant Area |
4,014,490
ft2
|
| Annual Production | 14,600,000
Tgal
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,238,409 | 27,735,043 |
kWh
|
$0.045 |
| Electricity Demand | $789,978 | 71,903 |
kW-mo/yr
|
$10.99 |
| Electricity Fees | $192,364 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $130,626 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $130,626 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4322: Use or replace with energy efficient substitutes | $85,489 | $171,258 |
$54,281
1,206,242
kWh
|
$31,208
-
kW-mo/yr
|
- | |
| 02 | 2.7135: Install occupancy sensors | $14,615 | $840 |
$10,945
243,215
kWh
|
$3,670
-
kW-mo/yr
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,526 | $45,190 |
$9,384
208,529
kWh
|
$3,142
-
kW-mo/yr
|
- | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,206 | $18,462 |
$8,393
186,514
kWh
|
$2,813
-
kW-mo/yr
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,264 | $5,922 |
$6,264
139,220
kWh
|
- | - | |
| 06 | 2.7134: Use photocell controls | $507 | $360 |
$507
11,257
kWh
|
- | - | |
| 07 | 2.8123: Pay utility bills on time | $19 | $80 | - | - | $19 | |
| TOTAL RECOMMENDED | $130,626 | $242,112 |
$89,774
1,994,977
kWh
|
$40,833
-
kW-mo/yr
|
$19 | ||
| TOTAL IMPLEMENTED | $130,626 | $242,112 |
$89,774
1,994,977
kWh
|
$40,833
-
kW-mo/yr
|
$19 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs