Assessment Year 2014
Principal Product Boats
NAICS 336612: Boat Building
SIC 3732: Boat Building and Repairing
Sales Range $10
M
to 50
M
# of Employees 93
Plant Area 40,000
ft2
Annual Production 295
pieces
Production Hrs. Annual 8,736
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $43,606 675,793
kWh
Electricity Demand $18,434 1,676
kW-mo/yr
Electricity Fees $12,512 -
Fuel Oil #2 $7,814 302
MMBtu
Other Energy $16,270 577
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $54,908 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $34,196

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Energy Savings Other Liquid (haz) Savings Administrative Changes Savings
01 3.8132: Use less toxic and volatile solvent substitutes $12,844 $14,320 - - - $12,031
-
gal
$813
02 3.5313: Increase amount of waste recovered for resale $8,400 $800 - - - - $8,400
03 3.8132: Use less toxic and volatile solvent substitutes $7,871 $640 - - - - $7,871
04 2.2437: Recover waste heat from equipment $7,868 $3,500 - - $7,868
-
MMBtu
- -
05 2.7145: Install skylights $5,746 $630 $4,656
72,159
kWh
$1,090
-
kW-mo/yr
- - -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,486 $1,310 $3,639
55,990
kWh
$847
-
kW-mo/yr
- - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $3,344 $9,120 $2,706
41,933
kWh
$638
-
kW-mo/yr
- - -
08 2.4231: Reduce the pressure of compressed air to the minimum required $2,899 $80 $2,349
36,142
kWh
$550
-
kW-mo/yr
- - -
09 2.7134: Use photocell controls $1,450 $360 $988
15,200
kWh
$462
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $54,908 $30,760 $14,338
221,424
kWh
$3,587
-
kW-mo/yr
$7,868
-
MMBtu
$12,031
-
gal
$17,084
TOTAL IMPLEMENTED $34,196 $12,940 $14,338
221,424
kWh
$3,587
-
kW-mo/yr
- - $16,271
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Other Energy Savings Other Liquid (haz) Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs