| Assessment Year | 2014 |
|---|---|
| Principal Product | Boats |
| NAICS | 336612: Boat Building |
| SIC | 3732: Boat Building and Repairing |
| Sales Range | $10 M to 50M |
| # of Employees | 93 |
| Plant Area |
40,000
ft2
|
| Annual Production | 295
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $43,606 | 675,793 |
kWh
|
$0.065 |
| Electricity Demand | $18,434 | 1,676 |
kW-mo/yr
|
$11.00 |
| Electricity Fees | $12,512 | - |
|
- |
| Fuel Oil #2 | $7,814 | 302 |
MMBtu
|
$25.86 |
| Other Energy | $16,270 | 577 |
MMBtu
|
$28.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $54,908 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $34,196 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Energy Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.8132: Use less toxic and volatile solvent substitutes | $12,844 | $14,320 | - | - | - |
$12,031
-
gal
|
$813 | |
| 02 | 3.5313: Increase amount of waste recovered for resale | $8,400 | $800 | - | - | - | - | $8,400 | |
| 03 | 3.8132: Use less toxic and volatile solvent substitutes | $7,871 | $640 | - | - | - | - | $7,871 | |
| 04 | 2.2437: Recover waste heat from equipment | $7,868 | $3,500 | - | - |
$7,868
-
MMBtu
|
- | - | |
| 05 | 2.7145: Install skylights | $5,746 | $630 |
$4,656
72,159
kWh
|
$1,090
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,486 | $1,310 |
$3,639
55,990
kWh
|
$847
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,344 | $9,120 |
$2,706
41,933
kWh
|
$638
-
kW-mo/yr
|
- | - | - | |
| 08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,899 | $80 |
$2,349
36,142
kWh
|
$550
-
kW-mo/yr
|
- | - | - | |
| 09 | 2.7134: Use photocell controls | $1,450 | $360 |
$988
15,200
kWh
|
$462
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $54,908 | $30,760 |
$14,338
221,424
kWh
|
$3,587
-
kW-mo/yr
|
$7,868
-
MMBtu
|
$12,031
-
gal
|
$17,084 | ||
| TOTAL IMPLEMENTED | $34,196 | $12,940 |
$14,338
221,424
kWh
|
$3,587
-
kW-mo/yr
|
- | - | $16,271 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Energy Savings | Other Liquid (haz) Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs