Assessment Year | 2014 |
---|---|
Principal Product | Ethnic Foods |
NAICS | 311412: Frozen Specialty Food Manufacturing |
SIC | 2038: Frozen Specialties, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 97 |
Plant Area |
28,000
ft2
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 3,744
hrs
|
Location (State) | Puerto Rico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $260,063 | 1,061,060 |
kWh
|
$0.25 |
Electricity Demand | $30,076 | 3,158 |
kW-mo/yr
|
$9.52 |
Electricity Fees | $2,400 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $126,163 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $101,066 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $68,259 | $15,600 |
$60,696
247,740
kWh
|
$7,563
-
kW-mo/yr
|
|
02 | 2.6218: Turn off equipment when not in use | $13,943 | $3,100 |
$12,400
50,611
kWh
|
$1,543
-
kW-mo/yr
|
|
03 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $13,113 | $19,160 |
$11,656
47,574
kWh
|
$1,457
-
kW-mo/yr
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,995 | $13,902 |
$7,081
28,903
kWh
|
$914
-
kW-mo/yr
|
|
05 | 2.7425: Clean or color roof to reduce solar load | $6,335 | $2,660 |
$5,630
22,980
kWh
|
$705
-
kW-mo/yr
|
|
06 | 2.7221: Lower temperature during the winter season and vice-versa | $5,027 | $80 |
$4,484
18,300
kWh
|
$543
-
kW-mo/yr
|
|
07 | 2.3212: Optimize plant power factor | $4,923 | $5,360 | - |
$4,923
-
kW-mo/yr
|
|
08 | 2.7111: Reduce illumination to minimum necessary levels | $3,989 | $440 |
$3,551
14,495
kWh
|
$438
-
kW-mo/yr
|
|
09 | 2.7135: Install occupancy sensors | $2,579 | $290 |
$2,293
9,358
kWh
|
$286
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $126,163 | $60,592 |
$107,791
439,961
kWh
|
$18,372
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $101,066 | $27,090 |
$85,503
348,989
kWh
|
$15,563
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs