Assessment Year 2013
Principal Product Adhesives and Sealants
NAICS 325520: Adhesive Manufacturing
SIC 2891: Adhesives and Sealants
Sales Range $10
M
to 50
M
# of Employees 80
Plant Area 75,000
ft2
Annual Production 156,000,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $87,146 1,665,600
kWh
Electricity Demand $45,125 4,472
kW-mo/yr
Electricity Fees $22,642 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $53,093 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $16,710

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $27,762 $68,060 $20,003
400,052
kWh
$7,759
-
kW-mo/yr
02 2.6218: Turn off equipment when not in use $4,361 $1,800 $3,140
62,790
kWh
$1,221
-
kW-mo/yr
03 2.7145: Install skylights $3,415 $2,780 $2,053
41,059
kWh
$1,362
-
kW-mo/yr
04 2.7425: Clean or color roof to reduce solar load $3,133 $2,600 $2,255
45,091
kWh
$878
-
kW-mo/yr
05 2.4231: Reduce the pressure of compressed air to the minimum required $3,214 $80 $1,925
38,491
kWh
$1,289
-
kW-mo/yr
06 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,120 $3,520 $2,247
44,928
kWh
$873
-
kW-mo/yr
07 2.7221: Lower temperature during the winter season and vice-versa $2,411 $80 $1,735
34,700
kWh
$676
-
kW-mo/yr
08 2.7142: Utilize higher efficiency lamps and/or ballasts $2,368 $2,340 $1,520
30,402
kWh
$848
-
kW-mo/yr
09 2.7135: Install occupancy sensors $2,117 $446 $1,522
30,433
kWh
$595
-
kW-mo/yr
10 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,192 $1,660 $225
4,499
kWh
$967
-
kW-mo/yr
TOTAL RECOMMENDED $53,093 $83,366 $36,625
732,445
kWh
$16,468
-
kW-mo/yr
TOTAL IMPLEMENTED $16,710 $6,846 $10,600
211,972
kWh
$6,110
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings