Assessment Year | 2012 |
---|---|
Principal Product | Cosmetics |
NAICS | 322291: Sanitary Paper Product Manufacturing |
SIC | 2676: Sanitary Paper Products |
Sales Range | $1 M to 5M |
# of Employees | 19 |
Plant Area |
23,000
ft2
|
Annual Production | 7,677,500
pieces
|
Production Hrs. Annual | 1,820
hrs
|
Location (State) | Puerto Rico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $114,926 | 499,455 |
kWh
|
$0.23 |
Electricity Demand | $34,342 | 3,565 |
kW-mo/yr
|
$9.63 |
Electricity Fees | $19,201 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $96,071 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $79,841 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $30,009 | $1,800 |
$23,516
102,242
kWh
|
$6,493
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,144 | $1,660 |
$17,367
75,507
kWh
|
$777
-
kW-mo/yr
|
- | |
03 | 4.821: Pay bills on time to avoid late fees | $13,801 | $480 | - | - | $13,801 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,235 | $2,050 |
$6,696
29,110
kWh
|
$539
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $6,801 | $800 |
$5,329
23,168
kWh
|
$1,472
-
kW-mo/yr
|
- | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,414 | $80 |
$5,547
24,116
kWh
|
$867
-
kW-mo/yr
|
- | |
07 | 2.3212: Optimize plant power factor | $4,040 | $4,550 | - |
$4,040
-
kW-mo/yr
|
- | |
08 | 2.4323: Use optimum size and capacity equipment | $3,835 | $4,691 |
$3,480
15,132
kWh
|
$355
-
kW-mo/yr
|
- | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,123 | $1,160 |
$2,449
10,647
kWh
|
$674
-
kW-mo/yr
|
- | |
10 | 2.6127: Maintain air filters by cleaning or replacement | $1,549 | $843 |
$1,212
5,271
kWh
|
$337
-
kW-mo/yr
|
- | |
11 | 2.2628: Utilize a less expensive cooling method | $1,120 | $1,498 |
$879
3,822
kWh
|
$241
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $96,071 | $19,612 |
$66,475
289,015
kWh
|
$15,795
-
kW-mo/yr
|
$13,801 | ||
TOTAL IMPLEMENTED | $79,841 | $6,823 |
$55,420
240,951
kWh
|
$10,620
-
kW-mo/yr
|
$13,801 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs