Assessment Year | 2012 |
---|---|
Principal Product | Food Product Machinery |
NAICS | 333318: Other Commercial and Service Industry Machinery Manufacturing |
SIC | 3589: Service Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
300,000
ft2
|
Annual Production | 1,000
pieces
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $216,594 | 2,478,116 |
kWh
|
$0.087 |
Electricity Demand | $68,502 | 8,155 |
kW-mo/yr
|
$8.40 |
Electricity Fees | $26,364 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $85,347 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,783 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $29,181 | $52,934 |
$20,487
235,490
kWh
|
$8,694
-
kW-mo/yr
|
|
02 | 2.6218: Turn off equipment when not in use | $13,778 | $1,800 |
$12,165
139,828
kWh
|
$1,613
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,280 | $1,660 |
$6,220
71,491
kWh
|
$2,060
-
kW-mo/yr
|
|
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,676 | $20,320 |
$4,685
53,848
kWh
|
$1,991
-
kW-mo/yr
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,448 | $80 |
$4,811
55,303
kWh
|
$1,637
-
kW-mo/yr
|
|
06 | 2.6218: Turn off equipment when not in use | $5,329 | $40 |
$3,741
42,998
kWh
|
$1,588
-
kW-mo/yr
|
|
07 | 2.7221: Lower temperature during the winter season and vice-versa | $4,050 | $200 |
$2,840
32,648
kWh
|
$1,210
-
kW-mo/yr
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,863 | $5,850 |
$2,712
31,163
kWh
|
$1,151
-
kW-mo/yr
|
|
09 | 2.6218: Turn off equipment when not in use | $2,772 | $545 |
$1,949
22,408
kWh
|
$823
-
kW-mo/yr
|
|
10 | 2.7496: Install partitions to reduce size of conditioned space | $2,072 | $5,800 |
$1,455
16,721
kWh
|
$617
-
kW-mo/yr
|
|
11 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,014 | $320 |
$712
8,185
kWh
|
$302
-
kW-mo/yr
|
|
12 | 2.7145: Install skylights | $978 | $1,920 |
$684
7,862
kWh
|
$294
-
kW-mo/yr
|
|
13 | 2.6218: Turn off equipment when not in use | $906 | $208 |
$637
7,319
kWh
|
$269
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $85,347 | $91,677 |
$63,098
725,264
kWh
|
$22,249
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $40,783 | $6,228 |
$31,810
365,634
kWh
|
$8,973
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs