Assessment Year 2012
Principal Product Car wash equipment
NAICS 333318: Other Commercial and Service Industry Machinery Manufacturing
SIC 3589: Service Industry Machinery, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 150
Plant Area 135,000
ft2
Annual Production 100,000
pieces
Production Hrs. Annual 3,146
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $74,739 1,307,280
kWh
Electricity Demand $39,736 4,217
kW-mo/yr
Electricity Fees $19,090 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $44,794 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $43,770

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.6218: Turn off equipment when not in use $18,962 $4,500 $13,958
193,856
kWh
$5,004
-
kW-mo/yr
02 2.7142: Utilize higher efficiency lamps and/or ballasts $18,605 $39,990 $12,429
172,621
kWh
$6,176
-
kW-mo/yr
03 2.7221: Lower temperature during the winter season and vice-versa $3,727 $1,300 $2,483
34,491
kWh
$1,244
-
kW-mo/yr
04 2.6218: Turn off equipment when not in use $1,412 $900 $941
13,073
kWh
$471
-
kW-mo/yr
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,064 $1,320 $747
10,378
kWh
$317
-
kW-mo/yr
06 2.4239: Eliminate or reduce compressed air usage $567 $610 $379
5,265
kWh
$188
-
kW-mo/yr
07 2.4231: Reduce the pressure of compressed air to the minimum required $457 $50 $296
4,109
kWh
$161
-
kW-mo/yr
TOTAL RECOMMENDED $44,794 $48,670 $31,233
433,793
kWh
$13,561
-
kW-mo/yr
TOTAL IMPLEMENTED $43,770 $48,010 $30,558
424,419
kWh
$13,212
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs