Assessment Year 2012
Principal Product Molded Products
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 31
Plant Area 22,300
ft2
Annual Production 300,000
pieces
Production Hrs. Annual 4,160
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $53,554 928,883
kWh
Electricity Demand $31,238 3,400
kW-mo/yr
Electricity Fees $14,223 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $21,771 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $16,464

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.6218: Turn off equipment when not in use $7,554 $8,000 $5,542
75,920
kWh
$2,012
-
kW-mo/yr
02 2.7425: Clean or color roof to reduce solar load $5,307 $8,856 $3,892
53,311
kWh
$1,415
-
kW-mo/yr
03 2.2136: Install / repair insulation on steam lines $3,759 $1,592 $2,758
37,781
kWh
$1,001
-
kW-mo/yr
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,170 $1,320 $1,591
21,795
kWh
$579
-
kW-mo/yr
05 2.7245: Use direct air supply to exhaust hoods $2,128 $500 $1,558
21,345
kWh
$570
-
kW-mo/yr
06 2.7496: Install partitions to reduce size of conditioned space $853 $3,656 $623
8,530
kWh
$230
-
kW-mo/yr
TOTAL RECOMMENDED $21,771 $23,924 $15,964
218,682
kWh
$5,807
-
kW-mo/yr
TOTAL IMPLEMENTED $16,464 $15,068 $12,072
165,371
kWh
$4,392
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs