Assessment Year | 2011 |
---|---|
Principal Product | Fruit Juice |
NAICS | 311411: Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
Sales Range | $100 M to 500M |
# of Employees | 100 |
Plant Area |
596,557
ft2
|
Annual Production | 80,000
Tgal
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,321,822 | 18,938,400 |
kWh
|
$0.070 |
Electricity Demand | $81,251 | 70,440 |
kW-mo/yr
|
$1.15 |
Electricity Fees | $42,507 | - |
|
- |
Natural Gas | $182,886 | 35,683 |
MMBtu
|
$5.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $126,005 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $83,661 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7425: Clean or color roof to reduce solar load | $25,532 | $213,119 |
$22,032
314,743
kWh
|
$3,500
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $25,191 | $41,400 |
$24,634
351,921
kWh
|
$557
-
kW-mo/yr
|
- | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $24,390 | $25,000 | - | - |
$24,390
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $22,111 | $1,320 |
$21,508
307,258
kWh
|
$603
-
kW-mo/yr
|
- | |
05 | 2.2447: Heat water with exhaust heat | $16,479 | $30,000 | - | - |
$16,479
-
MMBtu
|
|
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $5,771 | $1,950 | - | - |
$5,771
-
MMBtu
|
|
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,618 | $50 |
$3,438
49,113
kWh
|
$180
-
kW-mo/yr
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,475 | $1,720 |
$1,443
20,617
kWh
|
$32
-
kW-mo/yr
|
- | |
09 | 2.4323: Use optimum size and capacity equipment | $1,438 | $4,571 |
$1,408
20,111
kWh
|
$30
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $126,005 | $319,130 |
$74,463
1,063,763
kWh
|
$4,902
-
kW-mo/yr
|
$46,640
-
MMBtu
|
||
TOTAL IMPLEMENTED | $83,661 | $262,410 |
$73,020
1,043,146
kWh
|
$4,870
-
kW-mo/yr
|
$5,771
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs