Assessment Year | 2011 |
---|---|
Principal Product | Knit Beachwear |
NAICS | 315190: Other Apparel Knitting Mills |
SIC | 2253: Knit Outerwear Mills |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
275,000
ft2
|
Annual Production | 85,000,000
pieces
|
Production Hrs. Annual | 2,397
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $209,212 | 2,092,122 |
kWh
|
$0.100 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $46,606 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $42,124 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $24,647 | $9,000 |
$16,427
164,271
kWh
|
$8,220
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,531 | $62,700 |
$8,351
83,511
kWh
|
$4,180
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,679 | $1,320 |
$2,577
25,771
kWh
|
$1,102
-
kW-mo/yr
|
- | |
04 | 2.7135: Install occupancy sensors | $2,481 | $6,700 |
$1,651
16,511
kWh
|
$830
-
kW-mo/yr
|
- | |
05 | 2.4239: Eliminate or reduce compressed air usage | $2,001 | $1,980 |
$1,331
13,307
kWh
|
- | $670 | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,267 | $50 |
$819
8,187
kWh
|
$448
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $46,606 | $81,750 |
$31,156
311,558
kWh
|
$14,780
-
kW-mo/yr
|
$670 | ||
TOTAL IMPLEMENTED | $42,124 | $73,070 |
$28,174
281,740
kWh
|
$13,950
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs