| Assessment Year | 2011 |
|---|---|
| Principal Product | Boats |
| NAICS | 336612: Boat Building |
| SIC | 3732: Boat Building and Repairing |
| Sales Range | $10 M to 50M |
| # of Employees | 78 |
| Plant Area |
60,000
ft2
|
| Annual Production | 120
pieces
|
| Production Hrs. Annual | 2,397
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $48,002 | 722,880 |
kWh
|
$0.066 |
| Electricity Demand | $18,026 | 2,229 |
kW-mo/yr
|
$8.09 |
| Electricity Fees | $10,290 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $26,360 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $26,360 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $7,552 | $4,960 |
$5,465
51,561
kWh
|
$2,087
-
kW-mo/yr
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,382 | $17,910 |
$4,618
43,565
kWh
|
$1,764
-
kW-mo/yr
|
|
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $4,945 | $2,000 |
$3,578
33,759
kWh
|
$1,367
-
kW-mo/yr
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,155 | $1,210 |
$3,467
32,706
kWh
|
$688
-
kW-mo/yr
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,326 | $40 |
$2,528
23,852
kWh
|
$798
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $26,360 | $26,120 |
$19,656
185,443
kWh
|
$6,704
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $26,360 | $26,120 |
$19,656
185,443
kWh
|
$6,704
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs