Assessment Year 2009
Principal Product Tumbler Cups
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 65,000
ft2
Annual Production 2,000,000
pieces
Production Hrs. Annual 4,335
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $92,468 1,309,368
kWh
Electricity Demand $30,617 4,560
kW-mo/yr
Electricity Fees $31,451 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $51,277 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $35,199

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.6218: Turn off equipment when not in use $18,254 $3,320 $15,105
147
kWh
$3,149
-
kW-mo/yr
02 2.7142: Utilize higher efficiency lamps and/or ballasts $13,818 $15,466 $10,788
141,949
kWh
$3,030
-
kW-mo/yr
03 2.7496: Install partitions to reduce size of conditioned space $7,691 $13,320 $6,003
78,990
kWh
$1,688
-
kW-mo/yr
04 2.4231: Reduce the pressure of compressed air to the minimum required $6,725 $40 $3,785
29,797
kWh
$2,940
-
kW-mo/yr
05 2.7221: Lower temperature during the winter season and vice-versa $3,127 $2,000 $2,477
32,595
kWh
$650
-
kW-mo/yr
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,662 $1,210 $1,339
17,618
kWh
$323
-
kW-mo/yr
TOTAL RECOMMENDED $51,277 $35,356 $39,497
301,096
kWh
$11,780
-
kW-mo/yr
TOTAL IMPLEMENTED $35,199 $20,786 $28,370
174,691
kWh
$6,829
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs