Assessment Year | 2008 |
---|---|
Principal Product | Pharmaceutical Pill Packaging |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
130,000
ft2
|
Annual Production | 1,223,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $186,386 | 2,334,200 |
kWh
|
$0.080 |
Electricity Demand | $21,790 | 6,316 |
kW-mo/yr
|
$3.45 |
Electricity Fees | $31,049 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $162,825 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $68,048 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2628: Utilize a less expensive cooling method | $94,777 | $315,000 |
$89,854
1,041,397
kWh
|
$4,923
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $33,654 | $41,800 |
$31,197
361,080
kWh
|
$2,457
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $21,875 | $1,210 |
$20,446
236,644
kWh
|
$1,429
-
kW-mo/yr
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $8,496 | $40 |
$7,837
90,709
kWh
|
$659
-
kW-mo/yr
|
|
05 | 2.2511: Insulate bare equipment | $4,023 | $1,957 |
$3,405
36,150
kWh
|
$618
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $162,825 | $360,007 |
$152,739
1,765,980
kWh
|
$10,086
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $68,048 | $45,007 |
$62,885
724,583
kWh
|
$5,163
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs