Assessment Year 2007
Principal Product Mattresses
NAICS 337910: Mattress Manufacturing
SIC 2515: Mattresses, Foundations, and Convertible Beds
Sales Range $10
M
to 50
M
# of Employees 190
Plant Area 225,000
ft2
Annual Production 540,000
pieces
Production Hrs. Annual 5,200
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $114,780 1,796,800
kWh
Electricity Demand $38,376 5,904
kW-mo/yr
Electricity Fees $28,403 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $31,968 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,844

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7134: Use photocell controls $13,292 $3,157 $11,190
175,136
kWh
$2,102
-
kW-mo/yr
02 2.7145: Install skylights $6,818 $21,792 $4,900
76,677
kWh
$1,918
-
kW-mo/yr
03 2.7221: Lower temperature during the winter season and vice-versa $5,814 $120 $5,103
79,836
kWh
$711
-
kW-mo/yr
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,030 $1,074 $3,536
55,338
kWh
$494
-
kW-mo/yr
05 2.4231: Reduce the pressure of compressed air to the minimum required $2,014 $30 $1,768
27,669
kWh
$246
-
kW-mo/yr
TOTAL RECOMMENDED $31,968 $26,173 $26,497
414,656
kWh
$5,471
-
kW-mo/yr
TOTAL IMPLEMENTED $9,844 $1,194 $8,639
135,174
kWh
$1,205
-
kW-mo/yr
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs