Assessment Year | 2006 |
---|---|
Principal Product | Aluminum Tubing |
NAICS | 331318: Other Aluminum Rolling, Drawing, and Extruding |
SIC | 3354: Aluminum Extruded Products |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
150,000
ft2
|
Annual Production | 50,000,000
lb
|
Production Hrs. Annual | 6,600
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,311,464 | 17,556,420 |
kWh
|
$0.075 |
Electricity Demand | $412,640 | 52,167 |
kW-mo/yr
|
$7.91 |
Electricity Fees | $243,274 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $107,687 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $66,886 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $36,785 | $1,074 |
$31,595
422,962
kWh
|
$5,190
-
kW-mo/yr
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $26,909 | $30 |
$20,740
277
kWh
|
$6,169
-
kW-mo/yr
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $25,014 | $50,232 |
$21,407
286
kWh
|
$3,607
-
kW-mo/yr
|
|
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $15,787 | $40,200 |
$13,240
177
kWh
|
$2,547
-
kW-mo/yr
|
|
05 | 2.2437: Recover waste heat from equipment | $3,192 | $5,000 |
$3,192
93
kWh
|
- | |
TOTAL RECOMMENDED | $107,687 | $96,536 |
$90,174
423,795
kWh
|
$17,513
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $66,886 | $6,104 |
$55,527
423,332
kWh
|
$11,359
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs