ITAC Assessment: MI0136
ITAC logo
ITAC Assessment: MI0136
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2006
Principal Product Glass
NAICS 327215: Glass Product Manufacturing Made of Purchased Glass
SIC 3231: Glass Products, Made of Purchased Glass
Sales Range $5
M
to 10
M
# of Employees 115
Plant Area 100,000
ft2
Annual Production 4,000
thousand feet
Production Hrs. Annual 5,000
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $217,088 4,007,948
kWh
Electricity Demand $83,445 12,838
kW-mo/yr
Electricity Fees $27,052 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $50,586 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $44,032

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $36,851 $40,224 $35,115
641,128
kWh
$1,736
-
kW-mo/yr
-
02 2.7111: Reduce illumination to minimum necessary levels $4,544 $146 $4,443
81,120
kWh
$101
-
kW-mo/yr
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,741 $1,074 $3,134
57,213
kWh
$607
-
kW-mo/yr
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $2,010 $2,506 $1,587
28,971
kWh
$423
-
kW-mo/yr
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,760 - $1,370
24,986
kWh
$390
-
kW-mo/yr
-
06 2.8114: Change rate schedules or other changes in utility service $1,680 $100 - - $1,680
TOTAL RECOMMENDED $50,586 $44,050 $45,649
833,418
kWh
$3,257
-
kW-mo/yr
$1,680
TOTAL IMPLEMENTED $44,032 $41,398 $39,619
723,327
kWh
$2,733
-
kW-mo/yr
$1,680
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs