Assessment Year | 2006 |
---|---|
Principal Product | Industrial garbage bags |
NAICS | 326111: Plastics Bag and Pouch Manufacturing |
SIC | 2673: Plastics, Foil, and Coated Paper Bags |
Sales Range | $50 M to 100M |
# of Employees | 250 |
Plant Area |
100,000
ft2
|
Annual Production | 92,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,029,024 | 19,623,212 |
kWh
|
$0.052 |
Electricity Demand | $252,604 | 30,619 |
kW-mo/yr
|
$8.25 |
Electricity Fees | $167,121 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $107,533 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $35,320 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2136: Install / repair insulation on steam lines | $34,584 | $3,984 |
$28,701
499,144
kWh
|
$5,883
-
kW-mo/yr
|
|
02 | 2.7221: Lower temperature during the winter season and vice-versa | $25,742 | $46,506 |
$20,792
403,156
kWh
|
$4,950
-
kW-mo/yr
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,532 | $33,405 |
$10,859
228,883
kWh
|
$2,673
-
kW-mo/yr
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,597 | $1,074 |
$8,118
141,245
kWh
|
$2,479
-
kW-mo/yr
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $9,247 | $30 |
$6,457
112,352
kWh
|
$2,790
-
kW-mo/yr
|
|
06 | 2.4323: Use optimum size and capacity equipment | $9,084 | $4,800 |
$7,232
125,830
kWh
|
$1,852
-
kW-mo/yr
|
|
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,640 | - |
$2,154
41,264
kWh
|
$486
-
kW-mo/yr
|
|
08 | 2.4322: Use or replace with energy efficient substitutes | $2,107 | $3,878 |
$1,760
30,611
kWh
|
$347
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $107,533 | $93,677 |
$86,073
1,582,485
kWh
|
$21,460
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $35,320 | $43,157 |
$27,969
526,569
kWh
|
$7,351
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs