Assessment Year 2006
Principal Product Industrial garbage bags
NAICS 326111: Plastics Bag and Pouch Manufacturing
SIC 2673: Plastics, Foil, and Coated Paper Bags
Sales Range $50
M
to 100
M
# of Employees 250
Plant Area 100,000
ft2
Annual Production 92,000,000
lb
Production Hrs. Annual 8,400
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,029,024 19,623,212
kWh
Electricity Demand $252,604 30,619
kW-mo/yr
Electricity Fees $167,121 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $107,533 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $35,320

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.2136: Install / repair insulation on steam lines $34,584 $3,984 $28,701
499,144
kWh
$5,883
-
kW-mo/yr
02 2.7221: Lower temperature during the winter season and vice-versa $25,742 $46,506 $20,792
403,156
kWh
$4,950
-
kW-mo/yr
03 2.7142: Utilize higher efficiency lamps and/or ballasts $13,532 $33,405 $10,859
228,883
kWh
$2,673
-
kW-mo/yr
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,597 $1,074 $8,118
141,245
kWh
$2,479
-
kW-mo/yr
05 2.4231: Reduce the pressure of compressed air to the minimum required $9,247 $30 $6,457
112,352
kWh
$2,790
-
kW-mo/yr
06 2.4323: Use optimum size and capacity equipment $9,084 $4,800 $7,232
125,830
kWh
$1,852
-
kW-mo/yr
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,640 - $2,154
41,264
kWh
$486
-
kW-mo/yr
08 2.4322: Use or replace with energy efficient substitutes $2,107 $3,878 $1,760
30,611
kWh
$347
-
kW-mo/yr
TOTAL RECOMMENDED $107,533 $93,677 $86,073
1,582,485
kWh
$21,460
-
kW-mo/yr
TOTAL IMPLEMENTED $35,320 $43,157 $27,969
526,569
kWh
$7,351
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs