Assessment Year | 2005 |
---|---|
Principal Product | Glass Manufacturer |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
73,000
ft2
|
Annual Production | 3,750,000
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $255,833 | 5,059,200 |
kWh
|
$0.051 |
Electricity Demand | $120,239 | 14,601 |
kW-mo/yr
|
$8.23 |
Electricity Fees | $70,900 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $437,677 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $118,440 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.111: Add equipment/ operators to reduce production bottleneck | $319,237 | $91,320 |
$7,699
155,893
kWh
|
- | - | $311,538 | |
02 | 2.8121: Apply for tax-free status for energy purchases | $89,581 | $90 | - | - | $89,581 | - | |
03 | 4.652: Replace existing equipment with more suitable substitutes | $19,066 | $8,226 |
$14,718
297,310
kWh
|
$4,348
-
kW-mo/yr
|
- | - | |
04 | 2.8114: Change rate schedules or other changes in utility service | $6,289 | $600 | - | - | $6,289 | - | |
05 | 2.4239: Eliminate or reduce compressed air usage | $3,504 | $1,393 |
$3,504
61,361
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $437,677 | $101,629 |
$25,921
514,564
kWh
|
$4,348
-
kW-mo/yr
|
$95,870 | $311,538 | ||
TOTAL IMPLEMENTED | $118,440 | $10,309 |
$18,222
358,671
kWh
|
$4,348
-
kW-mo/yr
|
$95,870 | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs