Assessment Year | 2004 |
---|---|
Principal Product | Glass |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
60,000
ft2
|
Annual Production | 120,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $215,381 | 4,549,600 |
kWh
|
$0.047 |
Electricity Demand | $119,894 | 14,696 |
kW-mo/yr
|
$8.16 |
Electricity Fees | $55,485 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $512,988 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $479,120 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | Water Consumption Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $2,029 | - | - | - | $2,029 | - | - | |
02 | 2.6218: Turn off equipment when not in use | $28,772 | $2,300 |
$28,772
508,501
kWh
|
- | - | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $(-1,117.0) | $750 |
$963
19,351
kWh
|
$(-2,080.0) | - | - | - | |
04 | 2.4226: Use / purchase optimum sized compressor | $22,760 | $40,140 |
$760
15,277
kWh
|
- | $22,000 | - | - | |
05 | 4.111: Add equipment/ operators to reduce production bottleneck | $427,935 | - |
$(-1,185.0)
(-23,919)
kWh
|
$(-112,320.0) | - | - | $541,440 | |
06 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $17,529 | - |
$(-148.0)
(-2,686)
kWh
|
$(-1,200.0) | $18,877 | - | - | |
07 | 3.4111: Use closed cycle process to minimize waste water production | $14,310 | - | - | - | - |
$14,310
-
Tgal
|
- | |
08 | 4.821: Pay bills on time to avoid late fees | $770 | - | - | - | $770 | - | - | |
TOTAL RECOMMENDED | $512,988 | $43,190 |
$29,162
516,524
kWh
|
$(-115,600.0) | $43,676 |
$14,310
-
Tgal
|
$541,440 | ||
TOTAL IMPLEMENTED | $479,120 | $43,190 |
$29,310
519,210
kWh
|
$(-114,400.0) | $22,770 | - | $541,440 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | Water Consumption Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs