Assessment Year 2004
Principal Product Metal frame windows
NAICS 332321: Metal Window and Door Manufacturing
SIC 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 100,000
ft2
Annual Production 30,000
pieces
Production Hrs. Annual 2,250
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $35,230 691,342
kWh
Electricity Demand $21,648 2,773
kW-mo/yr
Electricity Fees $7,920 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $631,916 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Personnel Changes Savings Administrative Changes Savings Primary Product Savings
01 2.6218: Turn off equipment when not in use $2,732 $1,000 $4,032
67,916
kWh
$(-1,300.0) - -
02 4.111: Add equipment/ operators to reduce production bottleneck $600,000 $183,400 - - - $600,000
03 3.6193: Install equipment (eg compactor) to reduce disposal costs $28,289 $17,650 - - $28,289 -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $697 $590 $2,777
52,609
kWh
$(-2,080.0) - -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $198 - $198
3,777
kWh
- - -
TOTAL RECOMMENDED $631,916 $202,640 $7,007
124,302
kWh
$(-3,380.0) $28,289 $600,000
TOTAL IMPLEMENTED - - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs