| Assessment Year | 2004 |
|---|---|
| Principal Product | Metal frame windows |
| NAICS | 332321: Metal Window and Door Manufacturing |
| SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
100,000
ft2
|
| Annual Production | 30,000
pieces
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $35,230 | 691,342 |
kWh
|
$0.051 |
| Electricity Demand | $21,648 | 2,773 |
kW-mo/yr
|
$7.81 |
| Electricity Fees | $7,920 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $631,916 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $2,732 | $1,000 |
$4,032
67,916
kWh
|
$(-1,300.0) | - | - | |
| 02 | 4.111: Add equipment/ operators to reduce production bottleneck | $600,000 | $183,400 | - | - | - | $600,000 | |
| 03 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $28,289 | $17,650 | - | - | $28,289 | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $697 | $590 |
$2,777
52,609
kWh
|
$(-2,080.0) | - | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $198 | - |
$198
3,777
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $631,916 | $202,640 |
$7,007
124,302
kWh
|
$(-3,380.0) | $28,289 | $600,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs