Assessment Year | 2004 |
---|---|
Principal Product | Citrus fruit packaging |
NAICS | 311411: Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2030: |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
102,150
ft2
|
Annual Production | 15,000,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,851 | 2,122,080 |
kWh
|
$0.033 |
Electricity Demand | $47,156 | 5,786 |
kW-mo/yr
|
$8.15 |
Electricity Fees | $12,453 | - |
|
- |
LPG | $41,784 | 3,751 |
MMBtu
|
$11.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $221,288 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $168,750 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $20,512 | $600 | - | - | $20,512 | - | |
02 | 2.6218: Turn off equipment when not in use | $12,574 | $2,300 |
$12,574
245,103
kWh
|
- | - | - | |
03 | 2.6218: Turn off equipment when not in use | $3,925 | - |
$3,925
80,417
kWh
|
- | - | - | |
04 | 2.7492: Use proper thickness of insulation on building envelope | $6,702 | $3,693 |
$6,702
141,047
kWh
|
- | - | - | |
05 | 4.423: Move product using mechanical means | $168,750 | $6,904 | - | - | - | $168,750 | |
06 | 2.7134: Use photocell controls | $2,151 | $2,661 |
$2,151
45,276
kWh
|
- | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,680 | $2,670 |
$1,680
35,353
kWh
|
- | - | - | |
08 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $2,345 | $239 | - |
$2,345
-
MMBtu
|
- | - | |
09 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $2,649 | $15,260 |
$2,649
55,769
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $221,288 | $34,327 |
$29,681
602,965
kWh
|
$2,345
-
MMBtu
|
$20,512 | $168,750 | ||
TOTAL IMPLEMENTED | $168,750 | $6,904 | - | - | - | $168,750 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Administrative Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs