Assessment Year | 2004 |
---|---|
Principal Product | Perfumes and Cosmetics |
NAICS | 325611: Soap and Other Detergent Manufacturing |
SIC | 2844: Perfumes, Cosmetics, and Other Toilet Preparations |
Sales Range | $500 k to 1M |
# of Employees | 59 |
Plant Area |
50,000
ft2
|
Annual Production | 7,700,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $19,594 | 414,600 |
kWh
|
$0.047 |
Electricity Demand | $13,854 | 1,818 |
kW-mo/yr
|
$7.62 |
Electricity Fees | $4,474 | - |
|
- |
Natural Gas | $9,555 | 952 |
MMBtu
|
$10.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $57,620 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $50,471 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $1,283 | - |
$1,283
26,857
kWh
|
- | - | - | |
02 | 2.6218: Turn off equipment when not in use | $2,032 | $2,300 |
$2,032
42,640
kWh
|
- | - | - | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,535 | $1,370 | - |
$1,535
-
MMBtu
|
- | - | |
04 | 4.522: Modify storage space to avoid rental of a warehouse | $3,936 | $6,000 | - | - | $3,936 | - | |
05 | 2.8114: Change rate schedules or other changes in utility service | $3,834 | $400 | - | - | $3,834 | - | |
06 | 4.441: Install automatic packing equipment | $45,000 | $23,400 | - | - | - | $45,000 | |
TOTAL RECOMMENDED | $57,620 | $33,470 |
$3,315
69,497
kWh
|
$1,535
-
MMBtu
|
$7,770 | $45,000 | ||
TOTAL IMPLEMENTED | $50,471 | $30,770 | - |
$1,535
-
MMBtu
|
$3,936 | $45,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | Primary Product Savings |