Assessment Year | 2003 |
---|---|
Principal Product | Aircraft seat manufacturing |
NAICS | 336360: Motor Vehicle Seating and Interior Trim Manufacturing |
SIC | 2531: Public Building and Related Furniture |
Sales Range | $10 M to 50M |
# of Employees | 247 |
Plant Area |
107,000
ft2
|
Annual Production | 4,500
pieces
|
Production Hrs. Annual | 3,536
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $244,412 | 4,521,840 |
kWh
|
$0.054 |
Electricity Demand | $84,630 | 10,384 |
kW-mo/yr
|
$8.15 |
Natural Gas | $5,053 | 692 |
MMBtu
|
$7.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $173,958 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $51,279 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $46,943 | $600 | - | $46,943 | - | |
02 | 2.6218: Turn off equipment when not in use | $37,385 | $2,100 |
$37,385
848,350
kWh
|
- | - | |
03 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $7,200 | $3,222 | - | - | $7,200 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,203 | $3,536 |
$2,203
38,277
kWh
|
- | - | |
05 | 2.6218: Turn off equipment when not in use | $11,691 | - |
$11,691
250,059
kWh
|
- | - | |
06 | 2.4133: Use most efficient type of electric motors | $147 | $1,608 |
$147
3,151
kWh
|
- | - | |
07 | 2.7232: Replace existing hvac unit with high efficiency model | $68,389 | $68,389 |
$68,389
296,128
kWh
|
- | - | |
TOTAL RECOMMENDED | $173,958 | $79,455 |
$119,815
1,435,965
kWh
|
$46,943 | $7,200 | ||
TOTAL IMPLEMENTED | $51,279 | $5,636 |
$51,279
1,136,686
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs