Assessment Year 2003
Principal Product Floor access doors, grating, and pump lift stations
NAICS 332322: Sheet Metal Work Manufacturing
SIC 3444: Sheet Metal Work
Sales Range $5
M
to 10
M
# of Employees 132
Plant Area 142,720
ft2
Annual Production 0
pieces
Production Hrs. Annual 6,552
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $312,157 4,495,390
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $67,288 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $58,831

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $2,766 $3,951 $2,766
39,506
kWh
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $287 $24 $287
4,100
kWh
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $233 $458 $233
3,332
kWh
04 2.6218: Turn off equipment when not in use $57,321 $6,188 $57,321
818,865
kWh
05 2.7232: Replace existing hvac unit with high efficiency model $5,458 $32,500 $5,458
77,976
kWh
06 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $1,223 $9 $1,223
17,472
kWh
TOTAL RECOMMENDED $67,288 $43,130 $67,288
961,251
kWh
TOTAL IMPLEMENTED $58,831 $6,221 $58,831
840,437
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs