Assessment Year | 2003 |
---|---|
Principal Product | Drill bits |
NAICS | 332216: Saw Blade and Handtool Manufacturing |
SIC | 3545: Cutting Tools, Machine Tool Accessories, and Machinists' Precision Measuring Devices |
Sales Range | $5 M to 10M |
# of Employees | 100 |
Plant Area |
35,000
ft2
|
Annual Production | 35,000,000
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $66,262 | 1,185,077 |
kWh
|
$0.056 |
Electricity Demand | $51,992 | 6,463 |
kW-mo/yr
|
$8.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,202 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $6,926 | $1,000 | - | - | $6,926 | |
02 | 2.6218: Turn off equipment when not in use | $577 | $70 |
$577
8,243
kWh
|
- | - | |
03 | 2.6218: Turn off equipment when not in use | $7,079 | $884 |
$7,079
101,131
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,071 | $14 |
$1,071
15,063
kWh
|
- | - | |
05 | 2.4133: Use most efficient type of electric motors | $381 | $1,480 |
$231
3,357
kWh
|
$150
-
kW-mo/yr
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $315 | $286 |
$315
4,503
kWh
|
- | - | |
07 | 2.7124: Make a practice of turning off lights when not needed | $1,556 | $260 |
$1,556
22,230
kWh
|
- | - | |
08 | 2.6218: Turn off equipment when not in use | $9,297 | $4,420 |
$9,297
132,807
kWh
|
- | - | |
TOTAL RECOMMENDED | $27,202 | $8,414 |
$20,126
287,334
kWh
|
$150
-
kW-mo/yr
|
$6,926 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs