Assessment Year 2003
Principal Product Al and vinyl extrusions,Stnl.steel shapes
NAICS 326121: Unlaminated Plastics Profile Shape Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 70
Plant Area 92,622
ft2
Annual Production 2,000,000
lb
Production Hrs. Annual 0
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $61,320 1,419,630
kWh
Electricity Demand $35,165 4,479
kW-mo/yr
Electricity Fees $16,694 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $29,054 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,099

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $1,941 $5,300 $1,941
35,948
kWh
-
02 2.4231: Reduce the pressure of compressed air to the minimum required $176 $1 $176
2,925
kWh
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $768 $14 $768
14,222
kWh
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,001 $270 $1,001
18,537
kWh
-
05 2.6218: Turn off equipment when not in use $4,099 $50 $4,099
75,911
kWh
-
06 2.4322: Use or replace with energy efficient substitutes $2,007 $2,630 $1,264
23,082
kWh
$743
-
kW-mo/yr
07 2.4322: Use or replace with energy efficient substitutes $2,325 $3,350 $1,881
34,847
kWh
$444
-
kW-mo/yr
08 2.6218: Turn off equipment when not in use $16,737 $60 $16,737
309,944
kWh
-
TOTAL RECOMMENDED $29,054 $11,675 $27,867
515,416
kWh
$1,187
-
kW-mo/yr
TOTAL IMPLEMENTED $4,099 $50 $4,099
75,911
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs