Assessment Year | 2002 |
---|---|
Principal Product | Aluminum windows, sliding doors, curtains and walls for high rise buildi |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 27 |
Plant Area |
86,269
ft2
|
Annual Production | 34,425
pieces
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $25,759 | 398,400 |
kWh
|
$0.065 |
Electricity Demand | $8,371 | 1,152 |
kW-mo/yr
|
$7.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $195,172 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.423: Move product using mechanical means | $115,650 | $10,000 | n/a | - | - | - | $115,650 |
02 | 4.515: Install shelves / racks to utilize unused space | $73,631 | $42,600 | n/a | - | - | $73,631 | - |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $2,440 | $3,600 | n/a |
$1,505
22,464
kWh
|
$935
-
kW-mo/yr
|
- | - |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,734 | $1,300 | n/a |
$1,734
25,881
kWh
|
- | - | - |
05 | 2.7221: Lower temperature during the winter season and vice-versa | $1,717 | $7 | n/a |
$1,717
25,623
kWh
|
- | - | - |
TOTAL RECOMMENDED | $195,172 | $57,507 |
$4,956
73,968
kWh
|
$935
-
kW-mo/yr
|
$73,631 | $115,650 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs