ITAC Assessment: MI0016
ITAC logo
ITAC Assessment: MI0016
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2001
Principal Product Construction castings
NAICS
n/a
SIC 3321: Gray and Ductile Iron Foundries
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area 264,915
ft2
Annual Production 0
units
Production Hrs. Annual 4,992
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $585,112 10,835,415
kWh
Electricity Demand $191,456 23,578
kW-mo/yr
Natural Gas $242,840 28,425
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $211,646 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $77,381

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Water Disposal Savings Administrative Changes Savings Water Consumption Savings Primary Product Savings
01 4.431: Train operators for maximum operating efficiency $7,181 $3,300 - - - - $7,181
02 2.1133: Adjust burners for efficient operation $70,200 $187 $70,200
2,340,000
kWh
- - - -
03 3.4155: Meter waste water $8,529 $3,650 - $8,529
-
Tgal
- - -
04 2.1333: Convert combustion equipment to burn oil $21,440 $10,399 $21,440
731,231
kWh
- - - -
05 3.4151: Minimize water usage $6,397 $1,899 - - - $6,397
-
Tgal
-
06 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat $97,899 $585,000 - - $97,899 - -
TOTAL RECOMMENDED $211,646 $604,435 $91,640
3,071,231
kWh
$8,529
-
Tgal
$97,899 $6,397
-
Tgal
$7,181
TOTAL IMPLEMENTED $77,381 $3,487 $70,200
2,340,000
kWh
- - - $7,181
Yearly Savings* Imp'd Cost* Electricity Usage Savings Water Disposal Savings Administrative Changes Savings Water Consumption Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs