Assessment Year 2001
Principal Product Printed music
NAICS
n/a
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 240
Plant Area 116,111
ft2
Annual Production 11,320,000
pieces
Production Hrs. Annual 4,420
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $78,111 1,871,040
kWh
Electricity Demand $40,852 4,726
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $50,370 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $36,730

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Solid Waste (non-haz) Savings
01 2.7111: Reduce illumination to minimum necessary levels $4,216 $1,000 $4,216
43,421
kWh
- - -
02 2.7111: Reduce illumination to minimum necessary levels $7,470 $208 $7,470
99,568
kWh
- - -
03 2.7121: Utilize daylight whenever possible in lieu of artificial light $9,746 $280 $9,746
129,842
kWh
- - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,029 - $1,308
16,354
kWh
$721
-
kW-mo/yr
- -
05 3.6192: Use a less expensive method of waste removal $5,179 $5,000 - - $5,179
-
gal
-
06 3.5316: Contract a wood pallet recycling company $8,902 $306 - - - $8,902
-
lb
07 2.7221: Lower temperature during the winter season and vice-versa $3,176 $13 $3,176
17,090
kWh
- - -
08 2.7221: Lower temperature during the winter season and vice-versa $5,511 $13 $5,511
22,786
kWh
- - -
09 2.7232: Replace existing hvac unit with high efficiency model $4,141 $8,000 $4,141
42,653
kWh
- - -
TOTAL RECOMMENDED $50,370 $14,820 $35,568
371,714
kWh
$721
-
kW-mo/yr
$5,179
-
gal
$8,902
-
lb
TOTAL IMPLEMENTED $36,730 $6,612 $22,649
213,139
kWh
- $5,179
-
gal
$8,902
-
lb
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs