Assessment Year | 2001 |
---|---|
Principal Product | Screen printing and embroidery |
NAICS |
n/a
|
SIC | 2396: Automotive Trimmings, Apparel Findings, and Related Products |
Sales Range | $10 M to 50M |
# of Employees | 203 |
Plant Area |
70,000
ft2
|
Annual Production | 5,709,000
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $86,437 | 1,627,765 |
kWh
|
$0.053 |
Electricity Demand | $42,565 | 4,846 |
kW-mo/yr
|
$8.78 |
Natural Gas | $20,398 | 2,384 |
MMBtu
|
$8.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $177,285 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $5,105 | $2,513 |
$5,105
63,812
kWh
|
- | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $2,467 | $333 |
$2,467
30,832
kWh
|
- | - | |
03 | 2.1321: Replace fossil fuel equipment with electrical equipment | $16,244 | $2,084 |
$16,244
203,050
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,608 | $312 |
$4,608
57,600
kWh
|
- | - | |
05 | 2.7243: Improve air circulation with destratification fans / other methods | $22,646 | $7,000 | - | - | $22,646 | |
06 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,215 | $1,126 | - | $6,215 | - | |
07 | 4.122: Develop standard procedures to improve internal yields | $120,000 | $44,200 | - | - | $120,000 | |
TOTAL RECOMMENDED | $177,285 | $57,568 |
$28,424
355,294
kWh
|
$6,215 | $142,646 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs