Assessment Year | 2000 |
---|---|
Principal Product | Fresh atlantic salmon |
NAICS |
n/a
|
SIC | 2092: Prepared Fresh or Frozen Fish and Seafoods |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
11,200
ft2
|
Annual Production | 10,000,000
lb
|
Production Hrs. Annual | 4,625
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $115,918 | 1,091,735 |
kWh
|
$0.11 |
Electricity Demand | $15,905 | 2,710 |
kW-mo/yr
|
$5.87 |
LPG | $15,164 | 1,709 |
MMBtu
|
$8.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $86,821 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,894 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Fuel Oil #2 Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $66,856 | $175,000 |
$89,395
983,880
kWh
|
- |
$15,159
-
MMBtu
|
$(-52,698.0)
-
MMBtu
|
- | - | $15,000 | |
02 | 2.2136: Install / repair insulation on steam lines | $3,387 | $3,165 | - | - |
$3,387
-
MMBtu
|
- | - | - | - | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,100 | $6,600 |
$2,965
32,532
kWh
|
$1,374
-
kW-mo/yr
|
$(-1,239.0)
-
MMBtu
|
- | - | - | - | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,671 | $5,350 |
$1,958
21,395
kWh
|
$845
-
kW-mo/yr
|
$868
-
MMBtu
|
- | - | - | - | |
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $9,507 | $2,400 |
$(-273.0)
(-2,931)
kWh
|
$(-532.0)
-
kW-mo/yr
|
- | - | - |
$10,312
-
lb
|
- | |
06 | 3.4156: Use flow control valves on equipment to optimize water use | $300 | $463 |
$98
1,172
kWh
|
- | - | - |
$202
-
Tgal
|
- | - | |
TOTAL RECOMMENDED | $86,821 | $192,978 |
$94,143
1,036,048
kWh
|
$1,687
-
kW-mo/yr
|
$18,175
-
MMBtu
|
$(-52,698.0)
-
MMBtu
|
$202
-
Tgal
|
$10,312
-
lb
|
$15,000 | ||
TOTAL IMPLEMENTED | $12,894 | $5,565 |
$(-273.0)
(-2,931)
kWh
|
$(-532.0)
-
kW-mo/yr
|
$3,387
-
MMBtu
|
- | - |
$10,312
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Fuel Oil #2 Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs