Assessment Year | 1998 |
---|---|
Principal Product | dry wall board |
NAICS |
n/a
|
SIC | 3275: Gypsum Products |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
205,000
ft2
|
Annual Production | 325,000,000
thousand feet
|
Production Hrs. Annual | 8,384
hrs
|
Location (State) | New Hampshire |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,464,369 | 15,328,253 |
kWh
|
$0.096 |
Electricity Demand | $241,628 | 29,265 |
kW-mo/yr
|
$8.26 |
Electricity Fees | $6,022 | - |
|
- |
Natural Gas | $3,211,391 | 745,188 |
MMBtu
|
$4.31 |
Fuel Oil #2 | $11,191 | 2,843 |
MMBtu
|
$3.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $194,208 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $188,862 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Raw Material Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $67,656 | $52,600 | - | - |
$67,656
-
MMBtu
|
- | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $15,186 | $28,000 |
$15,186
162,954
kWh
|
- | - | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $10,928 | $2,675 |
$10,928
130,129
kWh
|
- | - | - | - | |
04 | 2.2511: Insulate bare equipment | $4,866 | $6,900 | - | - |
$4,866
-
MMBtu
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,171 | $1,923 |
$1,853
23,154
kWh
|
$318
-
kW-mo/yr
|
- | - | - | |
06 | 2.4133: Use most efficient type of electric motors | $1,309 | $1,457 |
$1,148
14,361
kWh
|
$161
-
kW-mo/yr
|
- | - | - | |
07 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,213 | $1,405 |
$1,016
12,603
kWh
|
$446
-
kW-mo/yr
|
$(-249.0)
-
MMBtu
|
- | - | |
08 | 2.4239: Eliminate or reduce compressed air usage | $466 | $225 |
$466
8,792
kWh
|
- | - | - | - | |
09 | 2.4322: Use or replace with energy efficient substitutes | $233 | $375 |
$233
2,931
kWh
|
- | - | - | - | |
10 | 4.222: Purchase re-conditioned material instead of new | $89,700 | $11,750 | - | - | - | $89,700 | - | |
11 | 3.5316: Contract a wood pallet recycling company | $480 | - | - | - | - | - | $480 | |
TOTAL RECOMMENDED | $194,208 | $107,310 |
$30,830
354,924
kWh
|
$925
-
kW-mo/yr
|
$72,273
-
MMBtu
|
$89,700 | $480 | ||
TOTAL IMPLEMENTED | $188,862 | $100,410 |
$30,830
354,924
kWh
|
$925
-
kW-mo/yr
|
$67,407
-
MMBtu
|
$89,700 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Raw Material Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs