Assessment Year | 1998 |
---|---|
Principal Product | icecream |
NAICS |
n/a
|
SIC | 2024: Ice Cream and Frozen Desserts |
Sales Range | $1 M to 5M |
# of Employees | 200 |
Plant Area |
33,460
ft2
|
Annual Production | 4,500
Tgal
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Vermont |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $288,954 | 6,065,944 |
kWh
|
$0.048 |
Electricity Demand | $198,892 | 14,499 |
kW-mo/yr
|
$13.72 |
Electricity Fees | $(-547.0) | - |
|
- |
LPG | $6,115 | 1,020 |
MMBtu
|
$6.00 |
Fuel Oil #2 | $25,215 | 4,714 |
MMBtu
|
$5.35 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $168,710 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $166,070 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $2,487 | $600 |
$2,487
16,706
kWh
|
- | - | - | - | - | |
02 | 4.652: Replace existing equipment with more suitable substitutes | $1,440 | - | - | - | - | - | - | $1,440 | |
03 | 2.2437: Recover waste heat from equipment | $1,240 | $2,100 |
$1,240
14,947
kWh
|
- | - | - | - | - | |
04 | 2.1113: Reduce combustion air flow to optimum | $1,020 | $400 | - |
$1,020
-
MMBtu
|
- | - | - | - | |
05 | 2.8121: Apply for tax-free status for energy purchases | $448 | - | - | - | - | $448 | - | - | |
06 | 4.131: Modify process to reduce material use/cost | $160,875 | $31,200 | - | - |
$6,435
-
lb
|
- | $154,440 | - | |
07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,200 | $1,850 | - | - |
$1,200
-
lb
|
- | - | - | |
TOTAL RECOMMENDED | $168,710 | $36,150 |
$3,727
31,653
kWh
|
$1,020
-
MMBtu
|
$7,635
-
lb
|
$448 | $154,440 | $1,440 | ||
TOTAL IMPLEMENTED | $166,070 | $34,300 |
$3,727
31,653
kWh
|
$1,020
-
MMBtu
|
$6,435
-
lb
|
$448 | $154,440 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs