Assessment Year | 1998 |
---|---|
Principal Product | storage and retrieval systems |
NAICS |
n/a
|
SIC | 3535: Conveyors and Conveying Equipment |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
48,000
ft2
|
Annual Production | 1,000,000
lb
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $39,025 | 535,756 |
kWh
|
$0.073 |
Electricity Demand | $17,154 | 2,030 |
kW-mo/yr
|
$8.45 |
Electricity Fees | $4,032 | - |
|
- |
Natural Gas | $23,289 | 3,182 |
MMBtu
|
$7.32 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,553 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,161 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,934 | $2,500 |
$4,019
69,754
kWh
|
$304
-
kW-mo/yr
|
$(-389.0)
-
MMBtu
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,602 | $11,858 |
$2,637
37,808
kWh
|
$965
-
kW-mo/yr
|
- | - | - | |
03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $2,513 | $8,600 | - | - |
$2,513
-
MMBtu
|
- | - | |
04 | 2.8121: Apply for tax-free status for energy purchases | $2,383 | - | - | - | - | - | $2,383 | |
05 | 2.2515: Use optimum thickness insulation | $1,126 | $1,700 | - | - |
$1,126
-
MMBtu
|
- | - | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $591 | $2,260 |
$245
3,517
kWh
|
$456
-
kW-mo/yr
|
$(-110.0)
-
MMBtu
|
- | - | |
07 | 2.2515: Use optimum thickness insulation | $392 | $90 |
$392
5,862
kWh
|
- | - | - | - | |
08 | 2.2515: Use optimum thickness insulation | $90 | $160 | - | - |
$90
-
MMBtu
|
- | - | |
09 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $4,922 | $3,036 | - | - | - |
$4,922
-
gal
|
- | |
TOTAL RECOMMENDED | $19,553 | $30,204 |
$7,293
116,941
kWh
|
$1,725
-
kW-mo/yr
|
$3,230
-
MMBtu
|
$4,922
-
gal
|
$2,383 | ||
TOTAL IMPLEMENTED | $19,161 | $30,114 |
$6,901
111,079
kWh
|
$1,725
-
kW-mo/yr
|
$3,230
-
MMBtu
|
$4,922
-
gal
|
$2,383 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs