Assessment Year | 1997 |
---|---|
Principal Product | frozen potatoes |
NAICS |
n/a
|
SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
13,500
ft2
|
Annual Production | 190,006,000
lb
|
Production Hrs. Annual | 7,000
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $223,925 | 3,414,420 |
kWh
|
$0.066 |
Electricity Demand | $60,047 | 6,240 |
kW-mo/yr
|
$9.62 |
Electricity Fees | $4,551 | - |
|
- |
LPG | $175,471 | 19,488 |
MMBtu
|
$9.00 |
Fuel Oil #2 | $89,365 | 15,495 |
MMBtu
|
$5.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $99,252 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $85,043 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Fuel Oil #2 Savings | Administrative Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.211: Consider use / purchase of bulk materials where possible | $58,961 | $46,000 | - | - | - | - | $58,961 | - | |
02 | 2.2443: Re-use or recycle hot or cold process exhaust air | $14,209 | $23,600 | - | - |
$14,209
-
MMBtu
|
- | - | - | |
03 | 2.2135: Repair and eliminate steam leaks | $5,656 | $857 | - | - | - |
$5,614
-
MMBtu
|
- |
$42
-
Tgal
|
|
04 | 2.4133: Use most efficient type of electric motors | $4,459 | $10,908 |
$3,571
41,325
kWh
|
$888
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,340 | $2,721 |
$1,859
41,325
kWh
|
$481
-
kW-mo/yr
|
- | - | - | - | |
06 | 4.821: Pay bills on time to avoid late fees | $3,664 | - | - | - | - | - | $3,664 | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,710 | $300 |
$1,710
26,377
kWh
|
- | - | - | - | - | |
08 | 3.4151: Minimize water usage | $6,304 | $19,800 |
$69
879
kWh
|
- | - |
$5,968
-
MMBtu
|
- |
$267
-
Tgal
|
|
09 | 3.4151: Minimize water usage | $1,949 | $232 | - | - | - | - | - |
$1,949
-
Tgal
|
|
TOTAL RECOMMENDED | $99,252 | $104,418 |
$7,209
109,906
kWh
|
$1,369
-
kW-mo/yr
|
$14,209
-
MMBtu
|
$11,582
-
MMBtu
|
$62,625 |
$2,258
-
Tgal
|
||
TOTAL IMPLEMENTED | $85,043 | $80,818 |
$7,209
109,906
kWh
|
$1,369
-
kW-mo/yr
|
- |
$11,582
-
MMBtu
|
$62,625 |
$2,258
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Fuel Oil #2 Savings | Administrative Changes Savings | Water Consumption Savings |