Assessment Year | 1996 |
---|---|
Principal Product | Canned Sardines |
NAICS |
n/a
|
SIC | 2091: Canned and Cured Fish and Seafoods |
Sales Range | $5 M to 10M |
# of Employees | 150 |
Plant Area |
27,250
ft2
|
Annual Production | 150,000
units
|
Production Hrs. Annual | 2,720
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $46,014 | 671,454 |
kWh
|
$0.069 |
Electricity Demand | $20,013 | 2,806 |
kW-mo/yr
|
$7.13 |
Electricity Fees | $4,731 | - |
|
- |
Fuel Oil #6 | $54,555 | 18,257 |
MMBtu
|
$2.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,292 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $2,700 | $4,950 | - | - |
$2,700
-
MMBtu
|
- | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,379 | $2,250 |
$1,597
22,860
kWh
|
$1,072
-
kW-mo/yr
|
$(-290.0)
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,884 | $9,867 |
$1,344
19,343
kWh
|
$540
-
kW-mo/yr
|
- | - | |
04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,860 | $3,140 | - | - |
$1,860
-
MMBtu
|
- | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,640 | $2,300 |
$585
8,499
kWh
|
$1,155
-
kW-mo/yr
|
$(-100.0)
-
MMBtu
|
- | |
06 | 2.2136: Install / repair insulation on steam lines | $1,013 | $846 | - | - |
$1,013
-
MMBtu
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $566 | $600 |
$566
8,206
kWh
|
- | - | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $461 | - |
$461
6,448
kWh
|
- | - | - | |
09 | 3.4151: Minimize water usage | $5,300 | $550 | - | - | - |
$5,300
-
Tgal
|
|
10 | 3.4151: Minimize water usage | $2,657 | $580 | - | - | - |
$2,657
-
Tgal
|
|
11 | 3.4111: Use closed cycle process to minimize waste water production | $1,693 | $3,100 | - | - | - |
$1,693
-
Tgal
|
|
12 | 3.4151: Minimize water usage | $1,139 | $1,200 | - | - | - |
$1,139
-
Tgal
|
|
TOTAL RECOMMENDED | $23,292 | $29,383 |
$4,553
65,356
kWh
|
$2,767
-
kW-mo/yr
|
$5,183
-
MMBtu
|
$10,789
-
Tgal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs