Assessment Year | 1995 |
---|---|
Principal Product | Circuit Boards |
NAICS |
n/a
|
SIC | 3577: Computer Peripheral Equipment, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 500 |
Plant Area |
311,000
ft2
|
Annual Production | 350,000,000
pieces
|
Production Hrs. Annual | 8,000
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,040,923 | 12,570,047 |
kWh
|
$0.083 |
Fuel Oil #6 | $69,872 | 22,025 |
MMBtu
|
$3.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $94,880 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,059 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #4 Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $44,899 | - | - | - | - | - | $44,899 | - | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $26,440 | $6,100 |
$32,790
395,955
kWh
|
$(-6,350.0)
-
MMBtu
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,133 | $3,264 |
$4,133
49,824
kWh
|
- | - | - | - | - | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,961 | $4,160 |
$3,616
43,669
kWh
|
$(-655.0)
-
MMBtu
|
- | - | - | - | |
05 | 2.2511: Insulate bare equipment | $1,858 | $2,365 | - | - | - | $1,858 | - | - | |
06 | 2.2443: Re-use or recycle hot or cold process exhaust air | $1,311 | $370 |
$1,311
13,189
kWh
|
- | - | - | - | - | |
07 | 2.7135: Install occupancy sensors | $1,260 | $300 |
$1,260
15,533
kWh
|
- | - | - | - | - | |
08 | 2.8123: Pay utility bills on time | $1,077 | - | - | - | - | - | $1,077 | - | |
09 | 3.4151: Minimize water usage | $4,092 | $60,000 | - | - |
$1,992
-
Tgal
|
- | - |
$2,100
-
Tgal
|
|
10 | 3.4114: Replace city water with recycled water via cooling tower | $6,122 | $650 | - | - | - | - | - |
$6,122
-
Tgal
|
|
11 | 3.4151: Minimize water usage | $727 | $440 | - | - |
$354
-
Tgal
|
- | - |
$373
-
Tgal
|
|
TOTAL RECOMMENDED | $94,880 | $77,649 |
$43,110
518,170
kWh
|
$(-7,005.0)
-
MMBtu
|
$2,346
-
Tgal
|
$1,858 | $45,976 |
$8,595
-
Tgal
|
||
TOTAL IMPLEMENTED | $12,059 | $4,354 |
$4,133
49,824
kWh
|
- |
$354
-
Tgal
|
- | $1,077 |
$6,495
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #4 Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs