Assessment Year 1994
Principal Product Dyed Wool Fabrics
NAICS
n/a
SIC 2231: Broadwoven Fabric Mills, Wool (Including Dyeing and Finishing)
Sales Range $10
M
to 50
M
# of Employees 300
Plant Area 160,000
ft2
Annual Production 18,000
thousand feet
Production Hrs. Annual 5,000
hrs
Location (State) Maine

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $652,506 7,854,045
kWh
LPG $79,374 15,273
MMBtu
Fuel Oil #2 $3,690 840
MMBtu
Fuel Oil #6 $266,615 120,958
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $100,086 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Fuel Oil #2 Savings Fuel Oil #6 Savings
01 2.7221: Lower temperature during the winter season and vice-versa $1,318 $2,800 - - $1,318
-
MMBtu
02 2.3212: Optimize plant power factor $4,574 $9,200 $4,574
-
kWh
- -
03 2.4221: Install compressor air intakes in coolest locations $1,730 $200 $1,730
20,809
kWh
- -
04 2.1311: Replace electrically-operated equipment with fossil fuel equipment $4,717 $4,300 $6,118
73,564
kWh
$(-1,165.0)
-
MMBtu
$(-236.0)
-
MMBtu
05 2.3416: Use combined cycle gas turbine generator sets with waste heat boilers connected to turbine exhaust $54,000 $110,000 $249,000
3,000,879
kWh
$(-195,000.0)
-
MMBtu
-
06 2.2449: Recover heat from exhausted steam, hot air or hot water $16,980 $18,000 - - $16,980
-
MMBtu
07 2.4322: Use or replace with energy efficient substitutes $16,767 $9,000 $16,767
201,641
kWh
- -
TOTAL RECOMMENDED $100,086 $153,500 $278,189
3,296,893
kWh
$(-196,165.0)
-
MMBtu
$18,062
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Fuel Oil #2 Savings Fuel Oil #6 Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs